Example: "Class Day" measurement sub-group has an error.
PacketShaper# measure show
Measurement engine is running
class month Interval:1h Samples: 1523712/ 1523712
link day Interval:1m Samples: 20160/ 20160
link month Interval:1h Samples: 8928/ 8928
partition day Interval:1m Samples: 1474560/ 1474560
class day Interval:1m Samples: 2949120/ 2949120 Error "0x10090001" ..........
partition month Interval:1h Samples: 761856/ 761856
If you issue the measure reset class command, the whole class group including Class Month data will be cleared.
Packet Shaper
Follow the steps below to clear the corrupted Class Day data without affecting the Class Month measurement data.
1. Delete the CL_day.dat from 9.258/measure/ directory manually,
# rm 9.258/measure/CL_DAY.DAT
# rm 9.258/measure/CL_Day.HDR
2. Restart the PacketShaper,
# reset
You can also delete these files using the File Browser in the Web interface. Then reset the PacketShaper. The CL_Day file will be automatically recreated.
Note: The ME class group is a separate entity from link, partition, and host groups.