Issue/Introduction

Does updating SymDump Batch's default tables such as CAOUDFRX or CAOETABL require an IPL? 

Environment

   

Resolution

SymDump Batch's default options tables are loaded into CSA so IPL is not required.
 Any modification of default options tables values are taken effect by following these required steps: 

 1) If the default options table was reassembled in a different library then HLQ.CAVHAUTH, then make sure the reassembled library is placed ahead of CAVHAUTH library in Link List.

2) Refresh LLA and Link List.

3) Refresh SymDump Batch runtime by running CAIRIM with RIMPARM(CAVHTERM) to deactivate runtime.
    PRODUCT(CA SYMDUMP/INTERTEST) VERSION(VHA0) INIT(CAVHTERM)
    And then rerun CAIRIM with RIMPARM(CAVHINIT) to activate runtime.

4) After successfully activate the SymDump Batch's runtime, run option report to verify your option value is changed.
     