All computers show a grey icon for the Health Status and they show up as Untracked in "vac_agenthealth" view table.
ITMS 8.7.x, 8.8.x
This can happen if the AC_AgentHealthSettings table is empty. You can check for this condition by running the following query:
select * from AC_AgentHealthSettings
If this returns no rows, then your agent health status will not work correctly.
Restore the default row with the following SQL. The statement adds the row only if it is missing.
IF NOT EXISTS (SELECT 1 FROM AC_AgentHealthSettings
WHERE PolicyGuid = '88AA67FA-A787-4F82-993A-E103E9530292')
INSERT INTO AC_AgentHealthSettings
(PolicyGuid,
CommunicationHealthEnabled, CommunicationHealthThreshold,
ConfigurationHealthEnabled, ConfigurationHealthThreshold,
BasicInventoryHealthEnabled, BasicInventoryHealthThreshold,
FullInventoryHealthEnabled, FullInventoryHealthThreshold,
StabilityHealthEnabled, StabilityHealthThreshold,
AgentVersionHealthEnabled,
CommunicationHealthThresholdMinutes,
ConfigurationHealthThresholdMinutes,
BasicInventoryHealthThresholdMinutes)
VALUES ('88AA67FA-A787-4F82-993A-E103E9530292',
1, 'DAY,1', 1, 'DAY,1', 1, 'DAY,1',
1, 'DAY,10', 1, 'DAY,30', 1,
1440, 1440, 1440);This will populate the default values in that table and allow your agents health data to work correctly.
If SQL Server reports an invalid column name for any of the three ThresholdMinutes columns, your release does not have them. Remove those three columns from the column list and the last three values from the VALUES list, then run the statement again.
Note: As always, make sure you have a current backup of your database before making any manual changes.
Verification:
Run
SELECT * FROM AC_AgentHealthSettings.
WHERE PolicyGuid = '88AA67FA-A787-4F82-993A-E103E9530292'
It returns one row. Open a computer’s Agent Health page in the Symantec Management Console and confirm the status is no longer Untracked.