You want to download the Symantec Security Information Manager (SSIM) 4.8.1 Patch 10 and review the readme and documentation for this patch. The patch and all documentation is attached to this document.
When trying to install the SSIM 4.8.1 patch from the Web Interface via Product LiveUpdate, it’s fails with the following error: Disk space check for 1400830774jtun_sim49lupkg_svr.jar failed
Note: The following items are different from previous patch requirements:
================================================================================
Symantec Security Information Manager 4.8.1 Patch 10
README.TXT
October 2014
Copyright (C) 2014 Symantec Corporation. All rights reserved. Symantec and
the Symantec Logo are trademarks or registered trademarks of Symantec
Corporation or its affiliates in the U.S. and other countries. Other names
may be trademarks of their respective owners.
The Licensed Software and Documentation are deemed to be "commercial
computer software" and "commercial computer software documentation" as
defined in FAR Sections 12.212 and DFARS Section 227.7202.
This README.TXT file includes following information:
* INFORMATION MANAGER 4.8.1 PATCH 10 FIXES
* MINIMUM REQUIREMENTS TO APPLY THE PATCH
* INFORMATION MANAGER DOCUMENTATION
* PATCH PRE-INSTALLATION PROCEDURES
* PATCH INSTALLATION
* SYSTEMS AFFECTED
================================================================================
INFORMATION MANAGER 4.8.1 PATCH 10 FIXES
================================================================================
Refer to Symantec_Security_Information_Manager_4.8.1_Patch_10_Release_Notes.pdf
for a list of fixes.
NOTE : Compared with SSIM 4.8 and prior Patch installers, SSIM 4.8.1 Patch
installer is updated to remove the password prompt for administrator user and
cn=root user.
================================================================================
MINIMUM REQUIREMENTS TO APPLY THE PATCH
================================================================================
* Apply this patch only to those SSIM Servers that are running Information
Manager 4.8.1
NOTE: SSIM 4.8.1 Patch 10 requires 700 MB of free disk space in the / and /opt
partitions.
The Patch can be installed using the LiveUpdate feature on the Information Manager
web console. To apply patch on all appliances, connect to the Information Manager
web console of each server and run LiveUpdate. The minimum disk space required
to install the Patch using the LiveUpdate is 3 GB in /tmp folder. If the available
disk space is less, you can download and run the patch installer.
You must disable the CacheMode option for Java LiveUpdate configuration in Information
Manager thick console.
================================================================================
INFORMATION MANAGER DOCUMENTATION
================================================================================
For more information about Symantec Security Information Manager, a knowledge
base is available on the Symantec Technical Support Web site at the following
URL:
http://www.symantec.com/business/support/overview.jsp?pid=52517
The knowledge base articles can be accessed from the Technical Solution section
or from the KB Articles link listed under the Product Support section. In the
Downloads section of the site, you can obtain files for your licensed product
including Agents, drivers, and patches. The SSIM manuals and guides can be
accessed from the Documentation section.
================================================================================
PATCH PRE-INSTALLATION PROCEDURES
================================================================================
Before you install the Patch, do the following:
* Save all work, backup any data and close any Information Manager console
sessions.
The SSIM Directory Servers must be updated first, starting with the primary
directory, then followed by all replica directories. All other SSIM Servers can
then be updated.
NOTE: There is no facility to roll back or uninstall the Patch.
================================================================================
PATCH INSTALLATION
================================================================================
1. Connect to the server using an account with administrative or root
privileges either by using an SSH client or by logging on locally.
2. Download the Symantec_Security_Information_Manager_4.8.1.810_Linux_EN.tar.gz
and .md5 files to the /tmp directory.
NOTE: You must use BINARY mode when transferring the files to the server.
Some FTP utilities use ASCII mode by default, which corrupts the
installation file.
3. Verify the integrity of the downloaded .tar.gz file by using a file
verification tool such as md5sum, which is included with the Linux
installation. If you use md5sum, execute the following command:
md5sum -c Symantec_Security_Information_Manager_4.8.1.810_Linux_EN.tar.gz.md5
NOTE: Both the .tar.gz and .md5 files must be present in the same directory
for md5sum to execute correctly.
For more information on md5sum, see the Linux man pages.
4. Unpack the patch by executing the following command:
tar -xvzf Symantec_Security_Information_Manager_4.8.1.810_Linux_EN.tar.gz
5. Change directory to the patch directory by executing the following command:
cd Patch10-481
6. Execute the following command:
sh install.sh
NOTE: The installer will automatically restart all the services when done.
The SSIM installation history file will be updated at /etc/ssim-history.
The Patch installation logs are available at
/opt/Symantec/simserver/logs/sima-upgrade_4.8.1.810.log
================================================================================
SYSTEMS AFFECTED
================================================================================
Only the SSIM Servers on which this Patch is applied will be affected.
================================================================================
END OF FILE
================================================================================