Unable to load libnsclic <No such file or directory>
search cancel

Unable to load libnsclic <No such file or directory>

book

Article ID: 16034

calendar_today

Updated On:

Products

CA Workload Automation AE - Business Agents (AutoSys) CA Workload Automation AE - Scheduler (AutoSys) Workload Automation Agent

Issue/Introduction



What does the below message mean? 

[03/07/2016 14:02:54] CAUAJM_E_90010 Unable to load libnsclic <No such file or directory>. 
[03/07/2016 14:02:54] CAUAJM_E_00102 Notification request aborted. 

Environment

Release: ATSYHA99000-11.3.5-Workload Automation AE-High Availability Option
Component:

Resolution

This message is an indication that a job(s) has a notification attribute set but Autosys is not able to do the notification because the integration with  NSM Notification Services (available only on Windows) is not set up. You would need to remove the notification related fields from the job definitions(JIL): "send_notification", "notification_id" and"notification_msg" job attributes, to stop the message.