SMP/E Apply for PTFs RO84681, RO84682, RO84683 looking for IMS RESLIB and resulting in IEW2303E errors
search cancel

SMP/E Apply for PTFs RO84681, RO84682, RO84683 looking for IMS RESLIB and resulting in IEW2303E errors

book

Article ID: 15875

calendar_today

Updated On:

Products

Gen Gen - Workstation Toolset Gen - Host Encyclopedia Gen - Run Time Distributed

Issue/Introduction



After downloading, receiving, and running an apply check successfully,

I am trying to Apply the RO84681, RO84682, RO84683 PTFs, but it is failing with these error messages:

     IEW2303E 1030 MEMBER DFSLI000 OF THE DATA SET SPECIFIED BY RESLIB COULD NOT BE FOUND. 

     IEW2303E 1030 MEMBER ASMTDLI OF THE DATA SET SPECIFIED BY RESLIB COULD NOT BE FOUND.

 

We do not currently have the IMS option as IMS has been removed from our site.

Environment

Release:
Component: CGBT

Resolution

Because you are trying to install RO84683, which is for the FMID CEHD850 for the CA GEN Common IMS Modules, you are getting errors. 

Please ensure that you do not have the CEHD850, CEG9850, CEKZ850 FMIDs still installed.

Then, APPLY only PTFs RO84681 and RO84682, not RO84683. 

 

Additional Information

We recommend only receiving and applying PTFs, not accepting them.

If these PTFs have been accepted already, then you may need to reinstall into a new CSI.