Getting error messages, during APPLY CHECK for a new Endevor PTF. ERROR DESCRIPTION AND POSSIBLE CAUSES RO96450 DOES NOT CONTAIN PNL C1SP1000 FROM SYSMOD TR96450. RO96450 DOES NOT CONTAIN PNL C1SP4000 FROM SYSMOD TR96450.
book
Article ID: 15795
calendar_today
Updated On:
Products
Endevor Software Change Manager (SCM)
Endevor Software Change Manager - Natural Integration (SCM)
Endevor Software Change Manager - ECLIPSE Plugin (SCM)
Endevor Software Change Manager - Enterprise Workbench (SCM)
Show More
Show Less
Issue/Introduction
While trying to add a new fix to Endevor I am getting the following messages:
RO96450 DOES NOT CONTAIN PNL C1SP1000 FROM SYSMOD TR96450.
RO96450 DOES NOT CONTAIN PNL C1SP4000 FROM SYSMOD TR96450.
How do i fix this?
Environment
Release: Component: ENDBAS
Resolution
Restore APAR TR96450 and remove it from your CSI, at this point you should then be able to apply PTF RO96450.
This procedure is true for any temporary fix that has been applied prior to the actual fix being installed.