After configuring a MySQL External Data Integration connection - during the data collection, the CCS Manager reports an error: The specified DSN contains an architecture mismatch between the Driver and Application.
12/11/2012 10:19:32,Job Exception Occurred,SQL query execution failed: ERROR [IM014] [Microsoft][ODBC Driver Manager] The specified DSN contains an architecture mismatch between the Driver and Application,,,,,
The architecture of the ODBC driver and DSN does not match the architecture of the Windows system.
If the data collection is done on a 64bit Windows system, make sure to install the 64bit MySQL ODBC drivers (mysql-connector-odbc-5.2.2-winx64.msi or similar) and configure the System DSN using the 64bit version of odbcad32.exe located in C:\Windows\System32, on that system.
If the data collection is done on a 32bit Windows system, make sure to install the 32bit MySQL ODBC drivers (mysql-connector-odbc-5.2.2-win32.msi or similar) and configure the System DSN using the 32bit version of odbcad32.exe located in C:\Windows\SysWOW64, on that system.
As you're reading this article, you might also be interested in the following articles:
Control Compliance Suite - External Data Integration - creating a MySQL Data Location - http://www.symantec.com/docs/TECH199623
Control Compliance Suite - MySQL External Data Integration - Error: You have an error in your SQL syntax. - http://www.symantec.com/docs/TECH199666
Applies To
Control Compliance Suite 10.x and 11.x
Windows 2003, 2008, 2008R2