Our monitoring team receives a number of alarms (interface_traffic probe) for devices that are admin down and not operationally down.
We only want to get alarms for devices that are operationally down.
How can we disable alarms for devices that are admin down?
The interface_traffic probe can be configured to alarm on both "operationally down" and / or "admin down".
To see the configuration options, use the IM console to open the configuration for the 'interface_traffic' probe.
Select one of the devices in the profile, and one of the interfaces.
Open the interface properties as shown in Figure 1. There is an option to "Ignore Operational State when admin state is not as expected".
Figure 1:
<Please see attached file for image>
src="/servlet/servlet.FileDownload?file=0150c000004AKZ0AAO" alt="interface_traffic_config.jpg" width="423" height="656">In the example above, given that option "Ignore operational state" is checked, here is what to expect:
Oper Down | Admin Down | Alarm |
Yes | Yes | admin down informational alarm |
No | Yes | admin down informational alarm |
Yes | No | Oper down major alarm |