After enabling PPA logging, no trace enabled output appears
search cancel

After enabling PPA logging, no trace enabled output appears

book

Article ID: 155022

calendar_today

Updated On:

Products

IT Management Suite

Issue/Introduction

The following steps are required to enable PPA debug output into the Altiris Log Viewer or debug viewer utility:

1. Create the Registry Key: HKEY_LOCAL_MACHINE\SOFTWARE\Altiris\PluggableProtocols\Debug
  a. Create a string value: 'Dest' in Debug with 'AltirisLog' as data.
  b. Create DWORD: 'Level' with value '0' to enable all logs.
2. Add entry in Altiris Log Viewer’s watch folder.
  a. Enable show hidden folders option.
  b. Goto Altiris Log Viewer file > Watch Folder > Add: “C:\ProgramData\Symantec\Symantec Agent\Logs"

No PPA Debug output appears

Environment

ITMS 8.x

Cause

After enabling PPA logging (via steps details above) , it is required to manually restart the Altiris services for reflecting PPA related Logs in Altiris Log Viewer or Debug utility.

Resolution