A SYSPROG is installing CA-7 Webviewer and the install guide references the Common Services JCL member WC20PROF to build the PROFILE dataset.
However this member does not exist.
Where or how to get this member?
You can simply create a PDS with the blocksize of 3120 and add the CCA7ENV member or run the following jobstream and add the CCA7ENV:
********************************* Top of Data **********************************
//WC20PROF JOB (ACCTINFO),'PMGR',CLASS=A,MSGCLASS=X
// JCLLIB ORDER=CAI.SAMPJCL <=== MODIFY NAME OF THIS LIBRARY
// INCLUDE MEMBER=CCSVARS
//********************************************************************
//*
//* PURPOSE: ALLOCATE AND CREATE
//* THE CA-VIEWPOINT PROFILE LIBRARY
//*
//* INSTRUCTIONS:
//*
//* 1. CHANGE THE JOB CARD PER INSTALLATION STANDARDS
//* 2. SPECIFY 'PVOL=' VALUE FOR PROFILE VOLSER
//* 3. CHECK IF OTHER DEFAULT SYMBOLIC VALUES IN PROC ARE ALSO OK
//* 4. RUN THE JOB
//* 5. CHECK THE RETURN CODE - EXPECTED RESULT RC = 0
//*
//* TAPE DRIVES REQUIRED: NONE
//*
//* REFERENCE: DSN=CAI.SAMPJCL(WC20PROF),LABEL=(9,SL) ON THE
//* CA COMMON SERVICES DISTRIBUTION TAPE.
//*
//********************************************************************
//WC20PROF PROC PVOL=, /* PROFILE LIBRARY VOLSER
// PERMDA=DISK, /* DASD UNIT PERM DEVICE
// SLQ=VPOINT /* SECOND LEVEL QUALIFIER
//ALLOCATE EXEC PGM=IEBUPDTE,PARM=NEW
//*
//* =========> CA VIEWPOINT PROFILE
//*
//* !!! NOTE: BLKSIZE MUST BE 3120 - DO NOT ALTER !!!
//SYSUT2 DD DSN=&PREFIX.&SLQ..PROFILE,DISP=(NEW,CATLG,DELETE),
// UNIT=&PERMDA,VOL=SER=&PVOL,SPACE=(3120,(50,10,10)),
// DCB=(RECFM=FB,LRECL=80,BLKSIZE=3120,DSORG=PO)
//SYSPRINT DD SYSOUT=A
// PEND
//*********************************************************************
//*
//* NOW EXECUTE THE PROC
//*********************************************************************
//ALLOC1 EXEC WC20PROF
//SYSIN DD *
./ ADD NAME=CACCENV,LIST=ALL
FASTPDS=PANEL,DIALOG,CAMAP,LIST,MESSAGE,SQL
SCR3270=NOSPF
SPFATTR=CA4FATTR
//