UMP and IM are not able to login to the hub

book

Article ID: 14579

calendar_today

Updated On:

Products

DX Infrastructure Management NIMSOFT PROBES

Issue/Introduction

When there is a robot installed on the server pointing to a drive C:\program files (x86)\Nimsoft and afterwards there is another robot and hub installed on the same server pointing to drive F:\nimsoft, the Nimsoft Robot Watcher Service will point to "C:\Program Files (x86)\Nimsoft\bin\nimbus.exe" instead to the new Path F:\Nimsoft. This will cause that the hub.exe process is never started by the controller out of the "C:\Program Files (x86)\Nimsoft\" location. You may also see a missmatch in installed versions.



Why can we not login to the hub with IM and UMP after the  installation of a robot and a hub.

Environment

UIM 8.xhub 7.xrobot 7.x

Resolution

 

The solution is to uninstall the robot from the C:\program files (x86)\Nimsoft verify the Nimsoft Robot Watcher Service has been removed from the Service Control panel.

Reinstall the robot and hub into the folder F:\Nimsoft  and verify you are now able to login to the hub with IM and UMP.