office365 probe fails with "connection abort" or "connection reset"
search cancel

office365 probe fails with "connection abort" or "connection reset"

book

Article ID: 145537

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

Office365 Probe Verify Selection works but the Profile goes into a Failure State when attempting to pull the Office 365 Inventory items list.

Errors captured in the office365.log :

office365] (1) error, Inventory update failed for %office365source%: Software caused connection abort: recv failed
Caused by: java.net.SocketException: Software caused connection abort: recv failed

OR

office365] (1) error, Inventory update failed for %office365source%: Connection reset
Caused by: java.net.SocketException: Connection reset

Environment

Release : 9.0.2

Component : UIM - OFFICE365

Cause

Office365 probe uses protocol TLS 1.1 with jave_jre versions prior to 1.80 and communicate fails.
Office365 probe requires java_jre version 1.80+ in order for the probe to communicate via TLS 1.2

Resolution

update the java_jre version to 1.8+ on the office365 robot

Additional Information


In the process of updating the Prerequisites section in the office365 (Office 365 Monitoring) Release Notes

https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-enterprise-software/it-operations-management/ca-unified-infrastructure-management-probes/GA/alphabetical-probe-articles/office365-office-365-monitoring/office365-office-365-monitoring-release-notes.html#concept.dita_f9838e3abf1efcda543d7734cbeff5387137b273_Prerequisites