Actions related to RO88433 and CICS TS 5.5 compatibility
search cancel

Actions related to RO88433 and CICS TS 5.5 compatibility

book

Article ID: 145367

calendar_today

Updated On:

Products

Top Secret Top Secret - LDAP

Issue/Introduction

Actions related to RO88433 

 

If Control Option 20 is on, then the following is needed.

                 

SMP APPLY, LLA REFRESH and recycle the CICS region.   

                                                                                 

If Control Option 20 is off, then set Control Option 20, 

SMP APPLY, LLA REFRESH and restart CA Top Secret with TSS,,,REINIT   

 

 

 

Environment

Release : 16.0

Component : CA Top Secret for z/OS

Resolution

Is a DEFACID defined on the facility?

If a DEFACID is defined then set option 20 in order to have DEFACID used instead of the CICS default user.

If the DEFACID and the CICS default user are the same acid, then remove the DEFACID acid from the facility.