Changes done in ibm_ds_next probe template are not being propagated

book

Article ID: 144773

calendar_today

Updated On:

Products

NIMSOFT PROBES DX Infrastructure Management

Issue/Introduction

In this scenario, using template editor, you have changed the auto filter thresholds for disks, by removing the values of "Minor Level 3" and "Warn Level 2" fields:



However, after saving it, the changes were not propagated, and values were not deleted:



Environment

UIM 9.2.0
ibm_ds_next 1.13

Resolution

This problem is solved by deploying ibm_ds_next-1.13-T1 probe version, by executing the following procedure:

1- Deactivate the ibm_ds_probe;

2- Take a full backup of the probe directory located in the respective robot, and place it outside the nimsoft directory structure;

3- Using IM console or Admin Console, delete the ibm_ds_next probe directory;

4- Deploy ibm_ds_next-1.13-T1 probe to the same robot;

5- Deactivate the probe;

6- In the probe directory, replace the "ibm_ds_next.cfg" file with the same file located in the backup taken. This will bring all the configuratons back again. 

7- Activate the probe


Please open a support case, in order to obtain this probe version.