Issue/Introduction

USM Alarm View does not display all alarms when fetchmsg probe alarm count is high

Environment

Release : 9.0.2

Component : UIM - FETCHMSG

Resolution

Use RAW Configure to removed the QSYSMSG queue from the probe's configuration

Section where the QSYSMSG queue was removed.

In this scenario only the QSYSOPR queue needs to be monitored.



Additional observations:

**The alarm count dropped significant 

**Resolved unknown alarms as well as alarms delays

Additional Information

Helpful UIM Community link

Help with AS400 Monitoring

Monitors specific message queue library with specific message queues with exceptions of certain info
FETCHMSG-probe: And you can add more MSGQ's in the Raw Configure in the "setup > queues > <new queue>"
Standard queues are: QSYSOPR and QSYSMSG