Issue/Introduction

The command: "uxlst fnc fnc=IO EXP" returns results for all areas, when it should only return results for the EXP area. 

$ ./uxlst fnc fnc=IO exp
 Command : uxlst fnc fnc=IO exp
 
FNC COMPANY NODE AREA STATUS START AT STOP AT ACTIVE AT PID CYCLE
--- ------- ---------------------------------------------------------------- ---- ------- ------------------------------------------------- ---------------------
IO TSTNDE nodename X Started 08/25/2019 0130 54190 0
IO TSTNDE nodename A Started 08/25/2019 0131 54727 0
IO TSTNDE nodename I Started 08/25/2019 0131 55020 0
IO TSTNDE nodename S Started 08/25/2019 0131 55222 0
 
Additionally,

uxend fnc fnc=IO exp

 stops the IO Server of Areas APP,INT,SIM but not the IO EXP

uxstr fnc fnc=IO exp 

starts the IO Server of Areas APP,INT,SIM but not the IO EXP

 

Environment

OS: All

Component: Application Server

Version: Dollar Universe v6.x

Resolution

The command "uxlst fnc fnc=io exp" returns all IO Areas as it has been conceived like that by Design.

Since Dollar Universe 6.10.21 , the commands "uxstr / uxstr fnc fnc=io exp" should fail with the following error:

1/ uxend fnc fnc=IO exp 
Command : uxend fnc fnc=IO exp

Incompatible area error
command in error!!

2/ uxstr fnc fnc=IO exp
Command : uxstr fnc fnc=IO exp

Incompatible area error
command in error!!