The Coupling Facility structure needs to be increased in size. What is needed in ACF2?
search cancel

The Coupling Facility structure needs to be increased in size. What is needed in ACF2?

book

Article ID: 143233

calendar_today

Updated On:

Products

ACF2 ACF2 - DB2 Option ACF2 for zVM ACF2 - z/OS ACF2 - MISC

Issue/Introduction

The Coupling Facility is over 80% used.  What needs to be done in ACF2 for the increase in size?  Can the existing information in the Coupling Facility be retained?

Environment

Release : 16.0

Component : CA ACF2 for z/OS

Resolution

The Coupling Facility is an "On Demand" use.  When something is needed and not in the CF, then a call is made and the data is added.  All that is needed in ACF2 is a stop and restart after the re-sizing is done.

F ACF2,SYSPLEX(STOP)

resize the CF structure

F ACF2,SYSPLEX(START)