Issue/Introduction

When using the project field Department as a virtual field in a custom subobject to the investment object, the object configuration properties reachable via the object list in the administration menu fail with popup message "Unable to process request - Server or Network error". The app-ca.log file reports:

ERROR 2019-12-09 12:34:16,354 [http-nio-8080-exec-795] web.VXSLServer (clarity:admin:5161193__4ADC1CC8-92A1-4A57-A564-95195F6A9E66:odf.objectProperties) Transformation error

; SystemID: file:/C:/niku/clarity/META-INF/union/vxsl/foundation.xsl; Line#: 1048575; Column#: -1

net.sf.saxon.trans.DynamicError: Error in call to extension function {public static java.lang.Boolean com.niku.union.xsl.ApiAliasExt.allowApiAlias(java.lang.String)}: Sequence contains more than one value; Java method expects only one

Cause

This is defect DE52328

 

Environment

Release : 15.7

Component : Clarity PPM APPLICATION

Resolution

The workaround is to delete the virtual attribute, go back to the properties tab and check the API Enabled option, then read the virtual attribute