When issuing Console commands for an IPL or Recycle of Top Secret the replies from the operator are not sent to the syslog. Is there a way to send the operator replies to the syslog?
P TSS
*TSS9072I ** SELECT TYPE OF SHUTDOWN ** <I> TO IGNORE
*TSS9072I <Z> END OF DAY; ** RE-IPL ** WILL BE REQUIRED
*41 TSS9072A <T> TEMPORARY; MAY IMPACT THROUGHPUT
Z41
IEE305I Z41 COMMAND INVALID
R 41 SUPPRESSED
IEE600I REPLY TO 41 IS;SUPPRESSED
*TSS9101W ***WARNING*** IPL WILL BE REQUIRED TO REINSTATE PROCESSING
*42 TSS9102A REPLY <Y> TO CONFIRM SYSTEM SHUTDOWN
R 42 SUPPRESSED
IEE600I REPLY TO 42 IS;SUPPRESSED
Release : 16.0
Component : CA Top Secret for z/OS
There is no way to have the reply posted in the sylog but there is a way to know what the reply was by the messages that are posted.
If seen in the log:
TSS9101W ***WARNING*** IPL WILL BE REQUIRED TO REINSTATE PROCESSING
TSS9102A REPLY <Y> TO CONFIRM SYSTEM SHUTDOWN
then Z was the reply.
If doing a temporary shutdown (T), the above 2 messages are not received.
If an invalid reply is issued (like X), the following is seen:
TSS9078I MODIFY OPTION IGNORED after the TSS9072I and A messages.
The reply messages do not show the actual reply but they are in the log in the form of:
IEE600I REPLY TO nnnn IS;SUPPRESSED .
The replies are not actual messages so they are not captured.