Merge Abend U0100 in ADSDM222+002ABA
search cancel

Merge Abend U0100 in ADSDM222+002ABA

book

Article ID: 142107

calendar_today

Updated On:

Products

Disk Backup and Restore - MVS DISK BACKUP AND RESTORE- ADD-ON OPTIO DISK BACKUP AND RESTORE

Issue/Introduction

Merge job abended with user abend U0100 in module ADSDM222+002ABA:

PET202I USER ABEND(U0100) AT PSW(078D1000 0010570A).        
PET206I ABEND OCCURRED AT PGM(ADSDM222.ADSDM222+002ABA)...

Environment

Release : 12.5

Component : CA Disk Backup and Restore

Resolution

The U0100 Abend is issued because the POINT macro for the output data set failed.
Following the related messages from MSGPRINT:
ADSDM222 9999 DDNAME=ARCHIVE1 POINT FAILURE PRV=013ADE6B 

It looks like that the POINT macro failed because of hardware problems with the tape device for which the following message was issued.
IOS000I D02E,**,SIM,**,**06,,**,EL6093,MERGE201