How do we define a different STC that will initialize ACF2 with a name different than ACF2? Tried to define ACF2D as an STC and after IPLing under ACF2, I stopped ACF2 and tried to start ACF2D. But, it wouldn't start. I received an error message stating that ACF2 wasn't initialized. Message is as follows:
0415 ACF9CCCC JESA , ACF2 SECURITY UNAVAILABLE, REPLY 'U' TO CONTINUE, 'C' TO CANCEL, OR 'W' TO WAIT IEF196I ACF9CCCC JESA , ACF2 SECURITY UNAVAILABLE, REPLY 'U' TO IEF196I CONTINUE, 'C' TO CANCEL, OR 'W' TO WAIT R 415,SUPPRESSED $HASP313 ACF2D JES2 IS UNABLE TO CREATE THE SECURITY ENVIRONMENT SECURITY PRODUCT RETURN CODE = 00000020 REASON CODE = 00000000
Release : 16.0
Component : CA ACF2 for z/OS
ACF2 can be started under any started proc name.
When using a started proc name to bring up ACF2 that does not equal ACF2, message ACF9CCCC will be issued. The ACF9CCCC message means that there is no current security and that you have to answer the question to continue. Choose one of the following 'REPLY 'U' TO IEF196I CONTINUE, 'C' TO CANCEL, OR 'W' TO WAIT'.
When starting ACF2 please select continue.