Following upgrade to UIM 9.2, WASP probe on cabi_external robot fails to start

book

Article ID: 141449

calendar_today

Updated On:

Products

NIMSOFT PROBES DX Infrastructure Management

Issue/Introduction

After upgrading UIM to 9.2, the WASP probe on the cabi_externl robot no longer starts successfully. The PID continually changes and it repeats a string of Apache errors, beginning with the below.

Nov 13 08:42:13:543 ERROR [Catalina-utility-1, org.apache.catalina.core.ContainerBase] startInternal() A child container failed during start

Nov 13 08:42:13:543 ERROR [Catalina-utility-1, org.apache.catalina.core.ContainerBase] java.util.concurrent.ExecutionException: org.apache.catalina.LifecycleException: Failed to start component [[email protected]]

Cause

The wasp probe is not required/used by the cabi_external probe.

The cabi probe was initially installed, but then replaced with the cabi_external probe.

Environment

Release : 9.0.2

Component : UIM - CABI

Resolution

The wasp probe can be safely deleted from the cabi_external robot since it is not used by this probe.