UIM / DX IM mon_config_service probe utility calls

book

Article ID: 141332

calendar_today

Updated On:

Products

NIMSOFT PROBES DX Infrastructure Management

Issue/Introduction

These mcs probe utility calls can be used to activate and check the status of templates and template packages. 

Environment

Release : 8.51 & 9.x 

Component : UIM - MON_CONFIG_SERVICE_TEMPLATES

Resolution

To use go to the Admin Console > primary hub > mon_config_service > View Probe Utility in New Window

Here are the more helpful calls and details on them. 

After running the callback, most will have an export button (a square with an arrow)

_status 
shows details of the probe

activate_probe_templates_package 
requires templates_package_version & probe_name
will activate all templates in the package 


activate_template
requires template_version & template_name


get_probe_templates_package_status
requires templates_package_version and probe_name 
shows all the templates, their version, & status that are in the package


list_template_versions
requires template_name

shows the version and ID

Additional Information

The SSRV2Template table will provide the template_version & template_name
The SSRV2Device table will provide the cs_id.
The SSRV2ProbeTemplatesPackage table provides the templates_package_version.