Issue/Introduction
I would like to know if you a procedure or a video how to create Time over threshold for a group of servers
from the side of Admin console or Infrastructure Manager
Environment
Release : 9.2.0
Component : UNIFIED INFRASTRUCTURE MGMT
Resolution
The ToT settings are not kept in the probe cfg files.
Instead, it is kept on the primary server in this file:
/opt/nimsoft/probes/service/nas/alarm_enrichment/alarm_enrichment.cfg
So, this prevents us from using a configuration superpackage to update a group of devices.
It is possible to individually set the ToT thresholds via the probe utility, but this is very cumbersome and can only be done one device at a time.
It is also possible to set the ToT thresholds via the Operator Console to groups.
So, unfortunately, the only realistic and supported way to set ToT for a group of devices is through the UMP or Operator Console.