Distsrv becomes unresponsive and hub is not upgraded to 9.20HF6
book
Article ID: 140467
calendar_today
Updated On:
Products
DX Infrastructure ManagementNIMSOFT PROBES
Issue/Introduction
I am trying to update the hub 9.20HF1 on the Primary Hub to 9.20HF6 release, but the Distribution View progress becomes unresponsive and the hub is never updated to HF6.
Cause
In the LD_LIBRARY_PATH value of the controller probe, there was a huge duplicated entry.
Environment
Release : 9.2.0
Component : UIM - HUB
Resolution
Just put a single value in the LD_LIBRARY_PATH: .:$LD_LIBRARY_PATH:.:.:
And the successfully updated the hub probe to 9.20HF6.