Excessive SVC 99 errors are seen in the Vantage started task (SAMS). It appears as if not all storage pools are defined in the Vantage parmlib:
VAN0901I GENSVC99 An SVC 99 error has occurred in dynamic -- allocation.
VAN0901I GENSVC99 ---- DISP=SHR
VAN0901I GENSVC99 ---- VOLUME=vvvvvv
VAN0901I GENSVC99 ---- UNIT=3390
VAN0901I GENSVC99 IKJ56893I UTILITY DATA SET NOT ALLOCATED+
VAN0901I GENSVC99 IGD17260I DATA SET XXXXXXX.XXXXXX.XXXX
VAN0901I GENSVC99 NOT ALLOCATED
VAN0901I GENSVC99 BECAUSE STORAGE GROUP SGRP1 NOT ENABLED
VAN0723I REFRESH of Automation Script SYSTEM GRPSTATS Done-CnMax=00000 Now=0000000000 ExMax=001 Now =000
Enabled
VAN0901I GENSVC99 An SVC 99 error has occurred in dynamic -- allocation.
VAN0901I GENSVC99 ---- VOLUME=FS8AC8
VAN0901I GENSVC99 IKJ56893I UTILITY DATA SET NOT ALLOCATED+
VAN0901I GENSVC99 ---- DISP=SHR
VAN0901I GENSVC99 ---- UNIT=3390
VAN0901I GENSVC99 IGD17260I DATA SET XXXXXXX.XXXXXX.XXXX
VAN0901I GENSVC99 ---- VOLUME=vvvvvv
VAN0901I GENSVC99 IKJ56893I UTILITY DATA SET NOT ALLOCATED+
VAN0901I GENSVC99 NOT ALLOCATED
VAN0901I GENSVC99 ---- UNIT=3390
VAN0901I GENSVC99 IGD17260I DATA SET XXXXXXX.XXXXXX.XXXX
VAN0901I GENSVC99 IKJ56893I UTILITY DATA SET NOT ALLOCATED+
VAN0901I GENSVC99 BECAUSE STORAGE GROUP SGRP2 NOT ENABLED
Vantage
The INCLEXCL Vantage parmlib member is needed and should define filters to exclude volumes that the various Vantage components try to access via the Vantage DTOC scan. Here is a sample of the components to modify, with example filters:
START-EXCLUDE-VOL Online Volumes
EXCL=PBS/
EXCL=PNG/
..
START-DTOCVEXC-VOL DTOC Volumes
EXCL=PBS/
EXCL=PNG/
..
START-DUPEDSNS-VOL Duplicate Data Sets (Volumes Checked)
EXCL=PBS/
EXCL=PNG/
..
START-VSAMVVDS-VOL VSAM Data Set Attributes (Volumes Checked)
EXCL=PBS/
EXCL=PNG/
Here is some documentation describing the INCLEXCL Vantage Parmlib member (see section 'INCLEXCL - Local PARMLIB Member'):
Configure Include/Exclude Statements