Issue/Introduction

- ARF INIT ERROR: RC=xxxx RS=rrrr INF=iiii


Reason:


An error has occurred during ARF initialization. The return, reason, and information codes define the problem exactly. In all probability ARF is not operational. ARF processing is disabled for this execution of CA Workload Automation CA 7 Edition. See the list of return codes that follows.

RC=0004


ARF is already initialized.

RC=0008


The ARF I/O routine, SASSARIO, was not loaded.

RC=0024


GETMAIN for an ARFIO (AIO) area failed.

RC=0028


GETMAIN for an ARFIO (AIO) buffer failed.


RC=0032

GETMAIN for an ARFIO (AIO) failed



Action:

Consider the following actions:


If ARF processing is required, a recycle of CA WA CA 7 Edition is needed after correcting the problem.

For RC 4, a recycle of CA WA CA 7 Edition typically cleans up the error.

For RC 8, ensure that the STEPLIB or linklist library contains the CA WA CA 7 Edition module SASSARIO.

The reason code is the return code from the IBM LOAD macro.



For RC 24,28, and 32, ensure that sufficient region is allocated to the address space.

The reason code is the return code from the IBM GETMAIN macro.


Environment

Release:


Component:

Resolution

Increase region size to 0M