Our daily update job failed with a U410 abend: 

In the MICSLOG for DAY040 the following message is displayed: 

CIC06120I +============================================================
CIC06120I INPUT PROCESSING FOR DDNAME INPUTSMF                        
CIC06120I +============================================================
BAS00345E ALL SYSTEM/COMPONENT ENTRIES IN CHECKPOINT USED             
BAS00345E USE CKPTLIMIT OPTION TO REMOVE UNNEEDED ENTRIES             
******************************** Bottom of Data ********************************

 

 

Environment

Release : 14.x

Component : MICS CICS ANALYZER

Resolution

In p.PARMS(SITE)

Increase the value for :: CKPTCNT nnn 

Pls do also backup p.CHECKPT.DATA before doing this.

save & exit then run in order

(1) p.CNTL(BASPGEN) .

(2) p.CNTL(CKPTINIT) This will resize the file with the value of nnn ..

After restart your job.

Additional Information

Refer to the following link regarding Vertical Checkpoint Expansion.

Later you might want to look at CKPTLIMIT in the PIOM.  It removes old entries that can cause this problem. 