CADD582E SYSTEM ADAPTER ERROR OCCURRED. FUNCTION=DYNLUB F/C=0000 R/C=00000018
search cancel

CADD582E SYSTEM ADAPTER ERROR OCCURRED. FUNCTION=DYNLUB F/C=0000 R/C=00000018

book

Article ID: 139083

calendar_today

Updated On:

Products

Dynam for VSE

Issue/Introduction

I ran this job and received the following error condition and cannot find the correct resolution in the Messages Manual

CA                                 D Y N A M / D    D I S K    M A I N T E N A N

CA DYNAM 7.1 0809YD000                                                                                                                                                                                                                                                                                                        
   DISPLAY '901 F7 EXPVSE' -                                                    
           POOL=111111 CHARSET=60 LRECL=132                                     
CADD582E SYSTEM ADAPTER ERROR OCCURRED. FUNCTION=DYNLUB   F/C=0000 R/C=00000018 
CADD562E FUNCTION ABNORMALLY TERMINATED, RETURN-CODE 008                        
CADD563I END OF DYNUTIL PROCESSING.   MAX.RETURN CODE=0008                     


Environment

Release: 7.1


Component: Dynam for VSE with System Adapter

Resolution

This situation can occur on any release but this is the advised solution.

You will need to increase the NPGR values in your ASI procedure.


We  do not know what your DYNLUB=(nnn,nnn) value is but you will need to increase the NPGR=nn   value or decrease the DYNLUB=  value