Issue/Introduction

JES2 receives an ACF2 violation against a proclib dataset on startup.

How can rules be written to allow JES2 to start if JES2 is not started?

Environment

Release : 16.0

Component : CA ACF2 for z/OS

Resolution

On re-IPL of the system, the start of JES2 failed due to an ACF99913 violation against one of the proclib datasets.

Start NET and TSO with SUB=MSTR so that they can start without JES2 being active.

Logon to TSO and make rule adjustments.