S0C4 abend in CAIRIM at IPL time
search cancel

S0C4 abend in CAIRIM at IPL time

book

Article ID: 138621

calendar_today

Updated On:

Products

COMMON SERVICES FOR Z/OS HYPER-BUF VSAM Buffer Optimizer

Issue/Introduction

Trying to apply an EKG key, getting the following message: CCSR010E CAIRIM S0C4 at 00E03AE8 LMOD N/A CSECT N/A +N/A CAS9 N/A CAS9. Twice on different days getting this message.


The first time, an IPL was required in order to apply the EKG key after IPL.


The second time, after the IPL, it was not possible to apply a new EKG key and getting the message error mentioned.



Environment

CA Common Services 14.1 - CA Hyperbuf 11.5 - z/OS supported releases - 


Resolution

This is an old problem of CA-Hyperbuf overlaying the CA Common Services CAFT control block.


Locating the Hyperbuf modules GVBDYNBF,FINDLLE,FINDJPA0 and GVB89CHK in storage and there is not the correcting PTF RO69204 applied. 


This PTF will need to be applied to the CA-Hyperbuf product but in order to clear the overlay, the system will need to be IPL'd.