ERROR: Could not restore template. Input buffer is corrupt
search cancel

ERROR: Could not restore template. Input buffer is corrupt

book

Article ID: 138404

calendar_today

Updated On:

Products

MICS Resource Management

Issue/Introduction

The following error is being received while running the Database Space Utilization report.  The job ends with a  CC=8

SYMBOLGEN:  Macro variable OBJNAME resolves to
MLOGIC(COPYOBJS):  Parameter OLIBIN has value MCOLIBIN
MLOGIC(COPYOBJS):  Parameter OLIBOUT has value MCOLIB
MLOGIC(COPYOBJS):  Parameter OBJTYPE has value CATALOG itemstor
MLOGIC(COPYOBJS):  Parameter OBJNAME has value
ERROR: Could not restore template. Input buffer is corrupt, or some other proble
ERROR: Could not restore template. Input buffer is corrupt, or some other proble
ERROR: Could not restore template. Input buffer is corrupt, or some other proble
ERROR: Could not restore template. Input buffer is corrupt, or some other proble
ERROR: Could not restore template. Input buffer is corrupt, or some other proble
ERROR: Could not restore template. Input buffer is corrupt, or some other proble

 .

.

ERROR: System abend 0C4 occurred in module SASODS function restore_yourself

Environment

Release : 14.1

Component : MICS

SAS: 9.4 TS1M6

Cause

Running with an older version of the SAS 9.4 SASHELP dataset

Resolution

Ensure that the SASHELP DD is at the same level as the other SAS libraries specified in the job.

When running 9.4 TS1M5 or TS1M6, if the SASHELP library specified is TS1M4 or prior this abend will occur.