Issue/Introduction

 

During a HMIG tape a S0C9 abend is occured: 

DSN=DFHSM.HMIGTAPE.DATASET,VOLS=W12544 IEF234E K 4860,W12544,PVT,HSMMAIN,HSMMAIN IEC501A M 486F,W12544,SL,COMP,HSMMAIN,HSMMAIN,DFHSM.HMIGTAPE.DATASET IECTMS9 486F,W12544,HSMMAIN ,SYS16172,PERMANENT ,00001,.HMIGTAPE.DATASET IEC205I SYS16172,HSMMAIN,HSMMAIN,FILESEQ=1, EXTEND VOLUME LIST, 195 DSN=DFHSM.HMIGTAPE.DATASET,VOLS=W12544 IEF234E K 486F,W12544,PVT,HSMMAIN,HSMMAIN IEC501A M 486C,W12544,SL,COMP,HSMMAIN,HSMMAIN,DFHSM.HMIGTAPE.DATASET IECTMS9 486C,W12544,HSMMAIN ,SYS16176,PERMANENT ,00001,.HMIGTAPE.DATASET IEC999I IFG0202F,HSMMAIN,HSMMAIN IEA794I SVC DUMP HAS CAPTURED: 207

DUMPID=002 REQUESTED BY JOB (HSMMAIN ) DUMP TITLE=IEC999I IFG0RR0A,IFG0RR0G,HSMMAIN ,HSMMAIN ,WORKAREA = 9A9B40 ARC0003I ARCMDSUV TASK ABENDED, CODE 840C9000 IN 208 ARC0003I (CONT.) MODULE UNKNOWN AT OFFSET 0000, STORAGE LOCATION ARC0003I (CONT.) 80D0CE52 IEA794I SVC DUMP HAS CAPTURED: 220 DUMPID=003 REQUESTED BY JOB (HSMMAIN ) DUMP TITLE=ARCMDSUV TASK ABENDED CODE=840C9000 IN MODULE UNKNOW N AT OFFSET=0000 STORAGE LOCATION=80D0CE52 IEF234E K 486C,W12544,PVT,HSMMAIN,HSMMAIN IEC501A M 4863,W12544,SL,COMP,HSMMAIN,HSMMAIN,DFHSM.HMIGTAPE.DATASET IEC147I 613-04,IFG0195B,HSMMAIN,HSMMAIN,SYS16180,4863,W12544, 253 DFHSM.HMIGTAPE.DATASET. ... ...............................

Environment

Release : 14.0

Component : CA 1 Tape Management

Resolution

 If a very small amount of data is written and then a close is performed the  attempt to calculate the compression ratio may result in a S0C9.

 The address space writing this very small amount of data to an existing  volume will abend. This is a known problem for CA View/Deliver, however

other products that go through CLOSE processing after writing very small  amounts of data may also be affected.

This problem is solved applying the RO98211.