Cannot save changes under Portal Settings in UMP control panel
Below error appears in Google Chrome Developer tools
Uncaught ReferenceError: _130_saveLdap is not defined
at _130_saveCompany (manage?p_p_id=130&p_p_lifecycle=0&p_p_state=maximized&p_p_mode=view&doAsGroupId=28862&refererPlid=10338:2)
at y.onSubmit (manage?p_p_id=130&p_p_lifecycle=0&p_p_state=maximized&p_p_mode=view&doAsGroupId=28862&refererPlid=10338:2)
at y._onValidatorSubmit (everything.jsp?browserId=other&themeId=controlpanel&colorSchemeId=01&minifierType=js&minifierBundleId=javascript.everything.files&languageId=en_US&b=6130&t=1565239560000:3)
at k.Method.exec (everything.jsp?browserId=other&themeId=controlpanel&colorSchemeId=01&minifierType=js&minifierBundleId=javascript.everything.files&languageId=en_US&b=6130&t=1565239560000:1)
at y.(/group/control_panel/anonymous function) [as _onValidatorSubmit] (htt
Release : UMP 9.2.0
Component : UNIFIED INFRASTRUCTURE MGMT
Please run following procedure:
1) Deactivate UMP robot wasp probe
2) Delete 'work' folder from the location ~\Nimsoft\probes\service\wasp
3) Edit the file edit_company.jsp located at ~\Nimsoft\probes\service\wasp\webapps\ROOT\html\portlet\portal_settings with the contents of the attached file edit_company_changes.txt starting at line 86 just before the close of the </aui:script> tag.
4) Clear browser cache
5) Activate UMP wasp probe