Working on applying maintenance for ACF2 and encountering following errors:
GIM24001E ** ASSEMBLER PROCESSING FOR SYSMOD SO05400 FAILED FOR MODULE ACFJ2ITF IN THE CAX1SRC0 LIBRARY. THE RETURN CODE
(08) EXCEEDED THE ALLOWABLE VALUE. DATE 19.240 - TIME 15:03:35.
** ASMA057E Undefined operation code - $MPRI/IILF
** ASMA435I Record 224 in SYS1.SHASMAC($MPRINT) on volume: xxxxxx
** ASMA057E Undefined operation code - $DORE/CLIJNE
** ASMA435I Record 80 in SYS1.SHASMAC($DORET) on volume: xxxxxx
Adding the following to the PARM operand on the assembly resolved the issue:
OPTABLE(UNI,NOLIST)
To make the change via SMP/E dialog options:
1 ADMINISTRATION
1 DEFINITION
ZONE NAME ===> GLOBAL
3 UTILITY
S ASMA90