Issue/Introduction

Upgrade Mainframe Application Tuner from V10 to V12.  When bringing up the V12 tasks I receive the following messages below. 

Is this an LMP code issue?  Where has the request for updates LMP keys site gone?

Or - is this the XCF group incompatibility with v10 tasks.  (I will be giving the V12 task a different XCFGroup name.)

20.38.05 STC08440  TN1008I CA MAT Version 12.0.00 started on 2019/08/20 at 20:38:05 <MATUNER >                                
20.38.05 STC08440  TN1102I Resolving LPALIST libraries <MATUNER >                                                                  
20.39.28 STC08440  TN3410I CA MAT module TNSSV42  loaded at 046F69A8 <MATUNER >                                                    
20.39.28 STC08440  TN1021I CA MAT SVC 042 filter installed at 00F980C8  <MATUNER >                                                 
20.39.28 STC08440  TN1010I CA MAT Server Space START complete <MATUNER >                                                           
20.39.30 STC08440  TN0040E PRODUCT LICENSE VALIDATION IS NOT ACTIVE ON YOUR SYSTEM.                                                
20.39.30 STC08440          CONTACT CA TECHNOLOGIES PRODUCT SUPPORT FOR ASSISTANCE. 
                                                
20.39.30 STC08440  TN1016I CA MAT Server is now terminating <MATUNER >                                                             
20.39.30 STC08440  TN1027I CA MAT SVC 042 filter is inactive                                                                       
20.39.30 STC08440  TN1017I CA MAT Server termination complete <MATUNER >                                                           
20.39.30 STC08440  ACTRT1I IEFACTRT                                CPU Total    Clock Time   CPU (TCB)    CPU (SRB)    zIIP Time   
20.39.30 STC08440  ACTRT2I Jobname  Stepname ProcStep    RC    I/O hh:mm:ss.th  hh:mm:ss.th  hh:mm:ss.th  hh:mm:ss.th  hh:mm:ss.th 
20.39.30 STC08440  ACTRT3I MATUNER  STARTING CAMAT       00  27245       04.19     01:28.58        03.97        00.22        00.00 
20.39.30 STC08440  IEF404I MATUNER - ENDED - TIME=20.39.30                                                                         
20.39.30 STC08440  ACTRT6I                                                                                                         
20.39.30 STC08440  ACTRT4I MATUNER  Job Service Totals       27245       04.19     01:28.60        03.97        00.22        00.00 
20.39.30 STC08440  IEF352I ADDRESS SPACE UNAVAILABLE                                                                               
20.39.30 STC08440  $HASP395 MATUNER  ENDED                                                                                         

Environment

Release : 12.0

Component : CA MAINFRAME APPLICATION TUNER

Resolution

It's not needed to have new keys when upgrading to a new release. LMPKEYS are only machine/lpar dependent, NOT release dependent.