Do the Netmaster subsystems support SSOB,SSIB,SSWT in 31 bit mode?
search cancel

Do the Netmaster subsystems support SSOB,SSIB,SSWT in 31 bit mode?

book

Article ID: 136022

calendar_today

Updated On:

Products

NetMaster Network Automation SOLVE NetMaster Network Management for SNA NetMaster Network Management for TCP/IP NetMaster File Transfer Management

Issue/Introduction

In z/OS 2.3 IBM introduced the option of moving the SSOB, SSIB and SSWT control blocks from 16 bit below the line storage to 31 bit above the line storage. The Netmaster for TCPIP subsystems (SOLV, OPER) are referring to some or  all of these control blocks (Func 9, 10 and 14). Do Netmaster subsystems support these blocks being above the line?



Environment

Release : 12.2

Component : CA NetMaster Network Management for TCP/IP

Resolution

Netmaster has no problems with these data structures being above the line. In the SSI intercepts using CA SysView "SUBSYS", it shows that  the SSVT for OPER and all of the subsystem routines for OPER and SOLV reside above the line. They are entered in 31-bit mode and stay in that AM.