We have downloaded fixes in order to update the product NETMASTER for TCP/IP and in the HOLDREPORT there are some fixes with HOLD=ACT where the procedure
described is incorrect.
The fix is SO06853 where we have the following:
//MYUSERV JOB ACCT,CLASS=A,MSGCLASS=X,NOTIFY=&SYSUID
//NMVIP EXEC PGM=NMVIP
//STEPLIB DD DISP=SHR,DSN=&TGTPREF.CC2DPLD
//MODSIN DD DISP=SHR,DSN=&TGTPREF.CC2DVSMI(MOD@$IP)
//MODSOUT DD DISP=SHR,DSN=&DSNPREF.MODSDIS
//SYSPRINT DD SYSOUT=*
//SYSIN DD *
COPY MODS INDD=MODSIN OUTDD=MODSOUT OPT=INSTALL
//*
//MYUSERV JOB ACCT,CLASS=A,MSGCLASS=X,NOTIFY=&SYSUID
//NMVIP EXEC PGM=NMVIP
//STEPLIB DD DISP=SHR,DSN=&TGTPREF.CC2DPLD
//PANLIN DD DISP=SHR,DSN=&TGTPREF.CC2DVSMI(PAN@$IP)
//PANLOUT DD DISP=SHR,DSN=&DSNPREF.PANLDIS
//SYSPRINT DD SYSOUT=*
//SYSIN DD *
COPY PANELS INDD=PANLIN OUTDD=PANLOUT OPT=INSTALL
//*
Release:
Component:
The dataset for DD cards MODSIN and PANLIN are incorrect.
Instead of pointing to CC2Dvsmi it should be CC11vsmi
The correct dataset is &TGTPREF.CC11VSMI