Tried the convert on a copy of our existing RMF. Received the following messages:


 


STMT NO                                    SYSIN DATA                      

  ------- --------------------------------------------------------------------

                                                                                   

     0001 CONVERT                                                            

          CAT3312I RMF CONVERSION STARTED                                    

          CAT3363E CONVERSION TABLE IS FULL                                      

          CAT3313I RMF CONVERSION COMPLETE                                        

          CAT3308I END OF RMF UPDATE REPORT    RC = 08

 

Environment

Release : 14.0

Component : CA TLMS Tape Management

Cause

Current RMF file is larger than the delivered RMF allocation.

Resolution

 CAT3363E

 CONVERSION TABLE IS FULL Reason: TLMSRMFE: During the conversion of the RMF from the old record format to the new format the RMF is read sequentially and the record keys are placed in a conversion table. The number of records in the RMF has exceeded the default number of entries in the table. Action: Change the override value in the EXEC PARM to equal or exceed the number of retention records in the RMF. The override for the conversion table is the first parameter in the PARM.  

Run again the proc overriding the PRM value to something looking like: PRM='32000,825,,1024'