Database Import Errors when Importing DBD's into the Telon Design Facility
search cancel

Database Import Errors when Importing DBD's into the Telon Design Facility

book

Article ID: 13447

calendar_today

Updated On:

Products

Telon Application Generator

Issue/Introduction

Importing Database Definitions to reload Telon Design Facillity Data Administration database with IMS DBD source information.

Imports show this error in the .rpt file: 

     PROCESSING ERROR ******** MESSAGE CODE NOT INTERPRETED. CODE = 009040  
     CONTACT CA TELON TECHNICAL SUPPORT HOTLINE                                        


Environment

Telon Application Generator, release 5.1

Resolution

This error appears when a logical DBD was imported before one of its referenced physical DBDs was imported. 

The Import order of Database Definitions into the Telon Design Facility's Data Administration should be:
1. Secondary index
2. Primary physical DBD
3. Logical DBDs.

As long as all Physical DBDs are imported before any Logical DBDs that reference a Physical DBD, the error will not occurred.