Can not start fault_correlation_engine, start after probe not enabled (relationship_services) AlarmID: NY58500064-96192 Origin: UIM-Primary-Hub-Backup SubSystem: Controller
Incident INC336021 is approaching SLC Resolution Criteria.
Short Description: Message: Can not start fault_correlation_engine, start after
Description: Message: Can not start fault_correlation_engine, start after probe not enabled (relationship_services) AlarmID: NY58500064-96192 Origin: UIM-Primary-Hub-Backup SubSystem: Controller
Release: UIM v8.5.1
Component : UIM - FAULT_CORRELATION_ENGINE
Deactivated the probes:
- fault_correlation
- topology_agent
- relationship_services
Saved off the probe directories in case they are needed in the future.
Rt-click and deleted those probes.
Removed the probe directories from the Primary and HA machines.
Adjusted the HA.cfg and removed the probes from the startup configuration.
Acknowledged the alarm.
You can choose to stop the robot and remove the controller.cfg sections pertaining to the 3 probes listed above as well.
Then Activate the robot again.