search cancel

Read Only Spectrum Service Performance Manager (SPM) tests no longer work after upgrade

book

Article ID: 134346

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

Read Only Spectrum Service Performance Manager (SPM) tests no longer work after upgrade. When trying to rediscovery the Read Only tests, the following errors are seen:

SPC-OCC-10182: The following error(s) occurred during test discovery:

SPC-OCC-11635: The model does not exist on the SpectroSERVER.

Environment

Release : Any version of Spectrum

Component : Spectrum Service Performance Manager (SPM)

Resolution

Delete the associated RTM_TestHost model. Spectrum will automatically create a new one. Then, run a Read Only discovery on the new RTM_TestHost model

Additional Information