EJCK Abend S80A from ISPF Edit session or from SDSF SJ session
search cancel

EJCK Abend S80A from ISPF Edit session or from SDSF SJ session

book

Article ID: 133834

calendar_today

Updated On:

Products

JCLCheck Workload Automation

Issue/Introduction

EJCK or !JCK command, issued in TSO/ISPF EDIT or from SDSF using the SJ line command gets ABEND S80A-10.  


Environment

Release : 12.0

Component :  JCLCheck workload Automation

Resolution

This is most likely due to the user's TSO ISPF PROFILE dataset reaching 100%.  Reallocate a larger ISPPROF data set to resolve the problem.  
If this doesn't solve the S80A abend, set a SLIP dump and open a case with Broadcom product support.  

Sample SLIP command:  /SLIP SET,COMP=80A,ACTION=SVCD,ID=EDCK,JOBNAME=xxxxxxxx,END 

*JOBNAME value is the TSO address space name