I upgraded CA Common Service to Version 15 and received error CAMS199E (CAMASTER FATAL INITIALIZATION ERROR) during IPL.
It appears that CAMASTER tried to initialize second time when it issued the CAMS111E and CAMS119E error messages.
====New Version 15 - IPL - Error Occurs====
CAMS100I CAMASTER INITIALIZATION IN PROGRESS
CAHC302I CA Health Checker r15.0 services are available
CAMS410I CAHCHECK started.
CAMS101I CAMASTER INITIALIZATION COMPLETE
CAMS410I CAHCHECK started.
CAMS101I CAMASTER INITIALIZATION COMPLETE
Approximately three seconds later, CA Master attempted to start a second time and the following messages were issued:
CCSI131I CCSEFXSR - POST-SECURITY PROCESSING
CCSI300I CCSMSI00 - INITIALIZATION STARTED
CAMS100I CAMASTER INITIALIZATION IN PROGRESS
CAMS111E CAMASTER IS ALREADY ACTIVE
CAMS199E CAMASTER FATAL INITIALIZATION ERROR
Release :
Component : CCS390 - CA COMMON SERVICES FOR Z/OS r15.0 SERVCS (CA-MASTER) executing in a z/OS 2.1 or later environment
There was an older copy of CCSEFXSR was found in LPA list which caused CA Master to start as it would for z/OS releases prior to z/OS 1.3