Getting messages CAS9320E and CAS9329E in ENF after upgrading Common Services from 14.1 to 15.0 with an existing Datacom/AD database
CADCOMT:DB00135I - CONNECT TO CADCOMT CXX14T STC06513 TEST M-14.0 I-14.0 0001
CADCOMT:DB00101I - STARTED JOB-CAIENF NUMBER-86750 CXX=CXX14T MUFNAME=CXX14T
CAS9337I - DBC/API initialized successfully.
CAS9320E - Conflicting #columns attribute detected in event xxxxxxxx.
CAS9329E - Recording is disabled for active event "xxxxxxxx".
These messages can indicate that PTF RO54507 was never installed and implemented at the 14.1 release level.
There were specific HOLD ACTION steps that were required to make the corresponding changes to the ENF database.
This PTF is included as part of the r15.0 code base and therefore the related HOLD ACTION steps need to be followed.
To verify what plans have been successfully imported, run the job documented in KD How to List Imported ENF Plans