unable to shutdown the ‘ESPAUX’ started task and re-cycle the product.

book

Article ID: 133023

calendar_today

Updated On:

Products

CA Workload Automation AE

Issue/Introduction

A re-ipl, I was advised to use the ‘RELOAD’ option within the PARMS which worked fine. However, when trying to shut down the product there are 3 started task running names ESPT, ESPW, and ESPAUXT. I was unable to shutdown the ‘ESPAUX’ started task  and re-cycle the product. Is there a way to shutdown ‘ESPAUX.

 

Environment

Release : 12.0

Component : CA ESP Encore Workload Automation

Resolution

The way to stop the AUX address space is to issue a modify command to the ESP STC.

EXAMPLE: To stop the CA WA ESP Edition auxiliary address space by issuing an AUX_AS CANCEL command

F ESP,AUX_AS CANCEL

If the STC is already down you can cancel using a FORCE ARM operator command.