SMP/E APPLY processing failed for IDMS PTF SO07191
search cancel

SMP/E APPLY processing failed for IDMS PTF SO07191

book

Article ID: 132903

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction

I receive the following error messages when trying to APPLY  PTF SO07191: 

IEW2456E 9207 SYMBOL MQBACK UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 
IEW2456E 9207 SYMBOL MQBUFMH UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 
IEW2456E 9207 SYMBOL MQCB UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 
IEW2456E 9207 SYMBOL MQCLOSE UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 
IEW2456E 9207 SYMBOL MQCMIT UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 
IEW2456E 9207 SYMBOL MQCONN UNRESOLVED.  MEMBER COULD NOT BE INCLUDED
IEW2456E 9207 SYMBOL MQCONNX UNRESOLVED.  MEMBER COULD NOT BE INCLUDED 


Environment

Release : 19.0

Component : CA IDMS/DB

Cause

There are HOLDDATA instructions in the PTF SO07191 that are required BEFORE the APPLY that were not performed.

In particular, in this instance the 

For example:



Resolution

The customer did not ADD or REPLACE the DDDEF(SCSQLOAD) to point to the IBM MQ SCSQLOAD as per the HOLDDATA instructions for PTF SO07191.


Additional Information

See the HOLDDATA Instructions for PTF SO07191

https://casupport.broadcom.com/download-center/solution-detail.html?aparNo=SO07191&os=OS