UIM HA probe 1.46 UMP Failover script not working
search cancel

UIM HA probe 1.46 UMP Failover script not working

book

Article ID: 132817

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

UMP Failover script not working with HA probe 1.46

Environment

HA probe 1.46

Cause

A defect in HA probe 1.46

Resolution

HA probe 1.47 and set "NAS_AO_first_if_failover = 1".
For details, see HA probe 1.47 Release Notes.

https://techdocs.broadcom.com/content/broadcom/techdocs/us/en/ca-enterprise-software/it-operations-management/ca-unified-infrastructure-management-probes/GA/alphabetical-probe-articles/ha-high-availability/ha-high-availability-release-notes.html

Additional Information

With NAS_AO_first_if_failover = 1, when the failover starts, the ha probe performs the actions in the following sequence:

1. Activates nas Auto Operator.
2. Issues "Initiating failover from remote Hub XXXXXX" alarm.
3. Activates queues configured in [Queues to enable].
4. Activates probes configured in [Probes to enable].