ADSDM175 message appeared in CA-DISK command after using IDB2.
book
Article ID: 132525
calendar_today
Updated On:
Products
Bind Analyzer for DB2 for z/OSSQL-Ease for DB2 for z/OSSYSVIEW Performance Management Option for DB2 for z/OSPlan Analyzer for DB2 for z/OSSubsystem Analyzer for DB2 for z/OS
Issue/Introduction
When the LISTDMS command of CA-DISK was issued on the ISPF panel after Sysview for DB2 was used in the same ISPF, the following error appeared.
ADSDM175 2056 PARAMETER CARD ENTERED THRU SYSPARMS DD STATEMENT IS IN ERROR ADSDM175 2056 VERIFY THE FORMAT IS CORRECT, CARD VALUE IS ( DEFAULTS )
The LISTDMS command was able to be issued without a problem if the Sysview for DB2 hadn't been used before the LISTDMS command was issued. It seems that CA-DISK can't refer the CA-DISK's SYSPARMS after using the Sysview for DB2 because the required datasets for the Sysview for DB2 are allocated dynamically for the SYSPARMS DD when the Sysview for DB2 is used. How should the LISTDMS command be done if the Sysview for DB2 is used before issuing that command?
Environment
z/OS, CA-DB2 R19.0, Sysview for DB2 R19.0, Sysview for DB2, R19.0, CA-DISK,
Resolution
The solution SO07831 was created on the Sysview for DB2 V19.0 for this problem. (The problem number IDB2 2389 on release 19.0.)